Practical Instrument Electronics
82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piecal.com
Page 1
PIECAL 422
Automated Thermocouple Calibrator
Operating Instructions
PIECAL 422
Automated Thermocouple Calibrator
Operating Instructions
Copyright © 2011 All rights reserved • 422-9002 - Rev C 13 July 2011
Product Description
Easy to use
With the PIECAL 422 you can check & calibrate all
your thermocouple instruments and measure
thermocouple sensors.
Take it without into the shop, plant or field
Carry it without worry - it comes protected with a
rubber boot and rugged, low profile switch. Easy to
operate even in the dark areas of the plant with the
backlit display.
Calibrate directly in temperature (°C & °F)
Stop carrying around a millivolt source and
thermocouple tables. The PIECAL 422 works with the
thermocouples you use including types J, T, E, K, R,
S, B, N, G, C, D, L (J-DIN), U (T-DIN) and Platinel II.
Easily set any value quickly to within 0.1° with the
adjustable digital potentiometer “DIAL plus store any
three temperatures for instant recall with the
EZ-CHECK™ switch.
Calibrate quickly with automatic output stepping
Choose between 2, 3, 5, 11 and 21 steps to
automatically increment the output in 100%, 50%,
25%, 10% or 5% of span. Select the step time to
match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30
and 60 seconds.
Compatible with all process instruments
Connect directly to the thermocouple inputs of smart
transmitters, PLCs, DCS and multichannel recorders
and verify their outputs or displays.
Measure Thermocouple Sensors
Trouble shoot sensor connections and find broken wires. The PIECAL 422 measures the
thermocouple in degrees C or F. Secondary display shows the millivolt value corresponding to
the thermocouple temperature as well as the cold junction temperature measured by the
calibrator.
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 2 - Connections

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 3 - Configuration

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 4 - Warranty

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 5 - Storing EZ-CHECK Outputs

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 6 - Ranges & Accuracies

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 7

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Strona 8 - PIECAL 422 Specifications

Practical Instrument Electronics82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piec

Komentarze do niniejszej Instrukcji

Brak uwag